HP ProLiant 100 Series servers
To enable the controller and set boot order:
- Power up the server.
- When prompted during the start-up sequence, access RBSU by pressing the F10 key.
- Select Advanced or Advanced Settings.
- Select SATA Configuration or Hard Drive Configuration or IDE Configuration.
- Change SATA #1 to RAID.
- Return to the previous screen by pressing the Escape key.
- Select the Boot Menu by pressing the right arrow key.
- Select Hard Disk Drives.
- To assign the HP Smart Array B110i SATA RAID Controller as the boot controller, set Ctrl 1 toHP Smart Array B110i SATA RAID Controller.
- Press the F10 key to save the setting and to exit RBSU.
HP ProLiant 200 and 300 Series servers
To enable the controller and set boot order:
- Power up the server.
- When prompted during the start-up sequence, access RBSU by pressing the F9 key.
- Select Advanced Settings.
- Select Embedded SATA RAID.
- Select Enabled.
- Return to the previous screen by pressing the Escape key.
- Select Boot Controller Order.
- To assign the HP Smart Array B110i SATA RAID Controller as the boot controller, set Ctrl 1 toHP Smart Array B110i SATA RAID Controller.
- Press the F10 key to save the settings and to exit RBSU.
No comments: